China Testing Instruments Manufacturer,Whatsapp/Wechat:+8619928310111  Email: 2601804145@qq.com

Musktool-AJ708 Current Voltage Transformer Tester
Musktool-AJ708 Current Voltage Transformer Tester
Musktool-AJ708 Current Voltage Transformer Tester
Musktool-AJ708 Current Voltage Transformer Tester

Musktool-AJ708 Current Voltage Transformer Tester

2024-08-01 11:16:09  

Musktool-AJ708 Current Voltage Transformer Tester

  • Main Feature :
  • Serial No. : monica0535
Contact Us For QuotationEmail:  464560351@qq.com  Whatsapp&Wechat:+8618620373879

Musktool-AJ708 Current Voltage Transformer Tester

Characteristic

★ Full-featured, not only satisfy the test requirements of various CTs (include TP class), such as the excitation characteristics (i.e., volt-ampere characteristics), ratio, polarity, secondary winding resistance, secondary burden, ratio error and phase displacement, but can also be used for the tests of various PTs, including excitation characteristics of the electromagnetic unit, ratio, polarity, secondary winding resistance, ratio error and phase displacement.

★ Automatically give CT, VT parameters, including knee point voltage / current, 10% error curve, the accuracy limit factor (ALF), instrument security factor (FS), the second time constant (Ts), remanence coefficient (Kr), saturated and unsaturated inductance etc.
★Test meet IEC60044 GB1208 (-1) GB16847 (IEC60044-6) became etc all kinds of transformer standards, and in accordance with the transformer types and levels of automatic choose which standard test.
★ Based on advanced principle of low-frequency test method that can meet the CT test on knee voltage up to 30KV.
★Friendly interface beautiful, all Chinese graphic interface.
★ The instrument can store 2000 groups of test data that won’t be lost when power off. After test ended, the data can be coped to PC by USB disk for analysis and being transformed into WORD report.
★ Test is simple and convenient, one-click can complete tests of CT secondary resistance, excitation, ratio and olarity.
★ Easy to carry, because the weight is less than 9Kg.

Technology features


Transformer Tester
Usage CT & VT
Output0~180Vrms,12Arms,18A(peak value)
CT RatioRange1~40000
accuracy±0.2%
PT RatioRange1~40000
accuracy±0.2%
PhaseRange±5min
accuracy0.5min
DC resistanceRange0~300Ω
accuracy2%±0.2VA
Power supplyAC220V±10%,50Hz
Environmental ConditionsOperating temperature :-10οC ~50οC,Humidity :≤90%
Weight and DimensionsDimensions:340 mm×300 mm×150mm,Weight<9kg















Telephone
Email
Map
QQ Chat