Musktool-ETCR2000B+ Explosion Proof Type Clamp Earth Resistance Tester is our company's technology research and development team on technical quality of the pursuit of excellence, through continuous innovation to improve, upgrade with the old product. Its performance is mainly reflected in:
Musktool-ETCR2000B + type clamp meter has passed the certification of explosion-proof and met GB3836-2000 explosive gas environment with electrical equipment. The explosion-proof marks is Exia Ⅱ BT3Ga. Explosion-proof qualified number: CE18.2380.It can be applied to the corresponding inflammable and explosive environment. |
Musktool-ETCR2000B+ Accessories
Earth tester
Test ring
Manual
Warranty card/Qualification card
Aluminum Case
TECHNICAL SPECIFICATION
Measurement Range & Accuracy
Measurement | Range | Resolution | Accuracy |
Resistance | 0.010Ω-0.099Ω | 0.001Ω | ±(1%rdg+0.01Ω) |
0.10Ω-0.99Ω | 0.01Ω | ±(1%rdg+0.01Ω) | |
1.0Ω-49.9Ω | 0.1Ω | ±(1%rdg+0.1Ω) | |
50.0Ω-99.5Ω | 0.5Ω | ±(1.5%rdg+0.5Ω) | |
100Ω-199Ω | 1Ω | ±(2%rdg+1Ω) | |
200Ω-395Ω | 5Ω | ±(5%rdg+5Ω) | |
400-590Ω | 10Ω | ±(10%rdg+10Ω) | |
600Ω-8800Ω | 20Ω | ±(20%rdg+20Ω) | |
900Ω-1200Ω | 30Ω | ±(25%rdg+30Ω) |
Technical Parameter
Function | Description |
Function | Test of earth resistance and loop resistance |
Power Supply | 6VDC 4 PCS of LR6 lkaline batteries |
Clamp Size | 65mm×32mm |
LCD Size | 4 Digits LCD display, Screen: 47mm×28.5mm |
Range | Resistance: 0.010Ω~1200Ω |
Resolution | Resistance: 0.001Ω |
Accuracy | Resistance: ±1%±0.01Ω; Current:±2.5%±1mA |
Data Storage | 99 sets |
Data Upload Function | RS232 Interface (Optional) |
Auto Power-off | Automatically power off after 5 minutes without any operation |
Power Consumption | ≤50mA, continuously working for 30 hours |
Working Environment | -20℃~55℃;20%rh~80%rh |
Store Environment | -20℃~60℃;below 90%rh |
EX-Mark | Ex ia Ⅱ BT3Ga |
Explosion-proof Certification | CE18.2380 |
Alarm Threshold Setting Range | Resistance:1~199Ω |
Audible and Visible Alarm | “Beep-beep-beep” alarm sound, alarm symbol flashing, press AL key to turn on/off and setting |
Interference Signal Recognition | “Beep-beep-beep” indicator, NOISE symbol blinking |
Protection Level | Double insulation |
Structural Feature | Clamp CT |
Shift | Automatic shift |
External Magnetic Field | <40A/m |
External Electrical Field | <1V/m |
Single Measurement Time | 0.5 second |
Resistance Measurement Frequency | >1KHz |
Measured Current Frequency | 50/60Hz Automatic |
Low Battery Voltage Indication | When the battery voltage is lower than 5.3V, the low battery voltage symbol is displayed |
Storage Full Indication | Storage data full of 99 sets,flashed display "MEM" symbol |
Over Range Indication | Over range indication “OLΩ”, “L0.01” or “OL A” |
Tester Weight | 1100g |
Tester Dimension | 285mm×85mm×56mm |
Measure the loop resistance
(Base on the formula: R=E/I)
Measure the grounding loop resistance system
(R1 is the measured earth resistance;
R0 is the equivalent resistance of the grounding resistor in parallel)
Two earth point measurement method
The RA is the measured grounding object, connecting RA
and RB (which is the nearly grounding object like as water
pipe or building) with one wire, the tester will test and indicate the concatenation resistance value of the ground
resistance and the test line resistance.
RT=RA+RB+RL
(RT is the tested value, RL is the test line resistance value)
Three earth point measurement method
(1).Connect the RA and RB with a test line; use the Meter to
get the first reading R1;
(2).Connect the RB and RC with a test line; use the Meter to
get the first reading R3;
(3).Connect the RA and RC with a test line; use the Meter to
get the first reading R2.
In the above three steps, the reading measured in each step is the value of the two series grounding resistance.
In this way, we can easily calculate the value of each grounding resistance,According to the reading value of R1,R2,R3:
R1=RA+RB; R2=RA+RC; R3=RB+RC
Then: RA=(R1+R2-R3)/2
As the reference points, the grounding resistance values of the other two grounding bodies
RB and RC are:
RB=R1-RA; RC=R2-RA
Field Application
The application of machine room earth resistance measurement
The machine room of telecommunication system normally in the upper deck of the building. It is hard to use the meg-ohm meter to measure. However, Musktool-ETCR Clamp meters are very convenient to test.
The application of substation earth resistance measurement
Musktool-ETCR series clamp meter can use to test the situation of contact and connect of circuit. With the help of one test line, it can be used to test the connect situation of equipment in station and the grounding system. Single point grounding measurement is allowed for the measurement of grounding resistance.
The application of building lightning protection grounding system measurement
If the earth poles of the building are independent of each other, the earth resistance can be measured by clamp to testing any of the earth poles, and the earth resistance can also be measured by clamp the building roof lightning arrester.When the measured value is less than the allowable value, the earth electrode is qualified.If the measurement value of the clamp meter is larger than the allowable value, please use ingle earth point method to measurement.
Related Series Model
Model | Clamp Size | Resistance Range | Current Range | Data Upload | Alarm | Data Save | Type |
Musktool-ETCR2000 | 55*32mm | 0.01-1000Ω | / | / | Yes | Yes | Basic |
Musktool-ETCR2000A | 55*32mm | 0.01-200Ω | / | / | Yes | Yes | Utility |
Musktool-ETCR2000C | 55*32mm | 0.01-1000Ω | 0.00mA-30.0A | / | Yes | Yes | Multifunction |
Musktool-ETCR2000+ | 65*32mm | 0.01-1200Ω | / | Optional | Yes | Yes | Basic |
Musktool-ETCR2000A+ | 65*32mm | 0.01-200Ω | / | Optional | Yes | Yes | Utility |
Musktool-ETCR2000B+ | 65*32mm | 0.01-1200Ω | / | Optional | Yes | Yes | Anti-explosion |
Musktool-ETCR2000C+ | 65*32mm | 0.01-1200Ω | 0.00mA-20.0A | Optional | Yes | Yes | Multifunction |
Musktool-ETCR2100+ | Φ32mm | 0.01-1200Ω | / | Optional | Yes | Yes | Basic |
Musktool-ETCR2100A+ | Φ32mm | 0.01-200Ω | / | Optional | Yes | Yes | Utility |
Musktool-ETCR2100C+ | Φ32mm | 0.01-1200Ω | 0.00mA-20.0A | Optional | Yes | Yes | Multifunction |
Musktool-ETCR2200 | 65*32mm | 0.01-1500Ω | 0.00mA-40.0A | Yes | Yes | Yes | High Performance |