Contact Us for Quotation | Email: mewoi008@mewoi.com | Whatsapp:+8619928420370 |
Musktool-CPL8100B-100A / 2MHz Current Probe (AC/DC)
Specification
Range level | L | H | |
Current range | 50mA~10A Peak | 1A~100A Peak | |
Attenuation accuracy | 0.1V/A | 0.01V/A | |
Typical DC precision | 3%±50mA | 500mA~40A Peak :4%±50mA;40A~100A Peak :±15% Maximum | |
Band-width | CPL8100A | DC-600kHz Refer to the typical Amplitude frequency characteristic (Figure 1) | |
(-3dB) | CPL8100B | DC-2MHz Refer to the typical Amplitude frequency characteristic (Figure 2) | |
Max current VS frequency | Figure 3 | ||
characteristics curve | |||
Phase shift | DC~65Hz:<1.5° | DC~65Hz:<1° | |
Typical DC linearity | The typical DC linearity at H level(0.01V/A), Figure 4 | ||
Rise time | CPL8100A | ≤583ns | |
CPL8100B | ≤175ns | ||
Max operation current | Please refer to voltage and current rating table | ||
Max operation voltage | Please refer to voltage and current rating table | ||
Max floating voltage | Please refer to voltage and current rating table | ||
Operating voltage RMS | CATI 600V CATII 600V CATIII 300V | ||
Common mode voltage RMS | CATI 600V CATII 600V CATIII 300V | ||
Typical battery type and life. | 9V alkaline layer-built battery/ 15H | ||
Low power indication | When battery voltage is lower than 6.5V, battery indicator will turned red and alert. | ||
Overload indication | When the current under test surpasses the range, the buzzer will buzz |