Contact Us For Quotation | Email: 464560351@qq.com | Whatsapp&Wechat:+8618620373879 |
INTRODUCTION
Musktool-ETCR2900B Earth Resistance Online Detector is high-tech product that our company has devoted to "grounding resistance detection technology research" for more than ten years, Using precision 3-wire or simple 2-wire measurement method to test the grounding resistance. Adopt average value rectification method to test grounding voltage, online detection, real-time monitoring. User can select RS232 or RS485 communication, according the protocol MODBUS to secondary development, build network, realize remote multipoint online monitoring etc.Musktool-ETCR2900B Earth Resistance Online Detector displayed by super large LCD, very clear and obvious. The alarm critical value can be set via the button, and with the sound and light alarm indication. Ensure the high accuracy, high stability and high reliability of real-time online monitoring of grounding resistance value in various place.Musktool-ETCR2900B Earth Resistance Online Detector Tester suitable for transmission line tower grounding, underground mine equipment grounding , weather lightning protection grounding, petrochemical grounding ,communication base station grounding, power substation grounding , railway grounding , building warehouse grounding , electrical equipment grounding, etc. |
Musktool-ETCR2900B Accessories
Detector
9P wiring terminal
Warranty card/Qualification card
Paper Box
SPECIFICATION
Measurement Range & Accurancy
Measurement Function | Range | Accuracy | Resolution |
Earth Resistance | 0.01Ω~20Ω | ±2%rdg±3dgt (auxiliary earth resistance 100Ω±5%,Voltage to earth<10V) | 0.01Ω |
0.1Ω~200Ω | ±2%rdg±3dgt (auxiliary earth resistance 100Ω±5%,Voltage to earth<10V) | 0.1Ω | |
1Ω~2000Ω | ±2%rdg±3dgt (auxiliary earth resistance 100Ω±5%,Voltage to earth<10V) | 1Ω | |
Earth Voltage | 0~600V AC | ±2%rdg±3dgt | 1V |
(Note: 23℃±5℃,below 75%rh)
Technical Parameter
Function | Description | ||
Measure Mode | Precise 3-wire measurement ,simple 2-wire measurement | ||
Measure Method | Ground resistance:rated current change-pole method,measured current11mA Max,128Hz; voltage to ground: average value ectification method. | ||
Power Supply | Standard:12V±1VDC、400mA Max(provided externally) | ||
Weight | Detector:380g | ||
Dimension | 130mm×90mm×54mm | ||
LCD Size | 47mm×28.5mm | ||
Measurement Time | Voltage to ground:about 2 times/second ; ground resistance : about 30 seconds/time | ||
Measurement Rate | Over 10000 times | ||
Monitoring Interval Time | Setting range of automatic monitoring interval time :1-999 h | ||
Instrument Interface | Pluggable terminal blocks: 9 pin connector | ||
Communication Method | RS485 or GPRS | ||
Data Storage | 99 groups,flash display “99” symbol indicate storage is full | ||
Data Access | Data read function :“READ” symbol display | ||
Overflow Display | Exceed measurement range overflow function :”OL” symbol display | ||
Alarm | Audible and visible alarm | ||
Power Supply Voltage | When power supply voltage decreases to about 10V , power supply low symbol will display, and remind to replace the power. | ||
Overload Protection | Measurement ground resistance: E-P, E-C between each interfaces AC 280V/3 seconds | ||
Electromagnetism | IEC61010-4-3,Wireless frequency electromagnetic field≤1V / m | ||
Line Voltage | Measuring the voltage to ground: Below AC 600V | ||
Accessories | Detector: 1PCS; GPRS Communication module+external antenna:1set(optinal),9P terminal block |
Structure & Size
Network Structure
Wireless Network System (Self -Development Software)
Wireless network system through GPRS communication protocol to transmit data ,build up by the detector(built-in GPRS transceiver module), 【SIM communication card, monitoring software, power adapter, computer(above equipment need the user provide and secondary development)】 and other components for long-distance ground resistance monitoring., distance is not limited.
Principle & Application
Measurement Principle
1.Earth voltage measurement adopts average value rectification method.
2.Earth resistance measurement adopts rated current change-pole method.
That is, the AC rated current I (11mA Max,128Hz) flows between the measuring
object E (ground electrode) and the C (current electrode); Get the potential difference
V between the E and the P (voltage electrode), and then get the grounding resistance
value Rx according to the formula: R=V/I.
3.The working error (B) is the error obtained within the rated working conditions, which is calculated from the inherent error (A) and variation error (Ei).
A: Intrinsic error E1: Variation due to position change
E2:Variation due to power supply voltage change E3:Variation due to temperature change
E4:Variation due to interference voltage change E5:Variation due to contact electrode resistance change
E7: Variation due to system frequency change E8: Variation due to system voltage change
Wiring Connection & Measurement Method
1.First: the user needs to make auxiliary grounding poles P and C every 5 ~ 10 meters on the same straight line near the monitored grounding pole E. Auxiliary grounding pole should adopt grounding materials or stainless steel material, prevent rust and rot, the grounding resistance value as small as possible, the general grounding resistance requirements no more than 100 Ω, ground voltage is less than 10V, so as to ensure the accuracy of the on-line monitoring.
Secondly: according follow table to connect the detector, computer, power supply, etc. It`s better that the connection between the detector and the auxiliary earth pole secured by electric power wire (for later maintenance and disassembly), or by welding.
2.The grounding resistance on-line monitoring usually adopts the precise three-wire method, but also can use the simple two-wire method to test. The simple two-wire method is used to measure the grounding resistance by using the existing grounding electrode which grounding resistance value is smaller as the auxiliary grounding electrode and short-connecting the C and P interfaces. Auxiliary grounding rods C and P can be instead by metal water pipes, fire hydrants and others metal embedded objects, common grounding of commercial power systems or lightning protection grounding poles of buildings, etc. During measuring, pay attention to removing the oxide layer at the connection point of the selected metal auxiliary grounding body. Simple two wires method wiring connection as right side figure:
The simple method measure the grounding resistance, the tester reading is the sum of the grounding resistance of the grounded body to be measured and the grounding resistance of the commercial grounding body.
R=RX+re
Which: R --- The tester reading value;
RX ---The grounding resistance value of measured grounding object;
re--- the grounding resistance value of a common grounding body such as a commercial power system.
Then, the earth ground resistance value of measured grounding body is:
RX=R-re
Use simple method to measure the grounding resistance, try best to select the grounding body with a smaller re value as the auxiliary grounding electrode, so that the detector reading is closer to the real value.
Related Series Model
Model | Range | LCD Size | Difference |
Musktool-ETCR2900 | 0.01Ω~2000Ω 0-600V AC | 128mm×75mm | Can build the Wired Network System |
Musktool-ETCR2900B | 0.01Ω~2000Ω 0-600V AC | 47mm×28.5mm | Can build the Wired Network System and Wireless Network System |