Contact US For Quotation | Email:464560351@qq.com | Whatsapp&Wechat:+8618620373879 |
Musktool-ZC2876/ZC2877/ZC2878 high frequency LCR digital bridge
Description
Brief introduction
The high-frequency precision bridge is a multi-function component tester for testing various electronic components. It uses the most popular 7-inch 800x480 color TFT LCD display, which enables users to read test results more intuitively and comfortably. It is an impedance measuring instrument with high speed, wide test range and 6-bit test resolution, which can meet the requirements of production line quality assurance, incoming inspection and laboratory measurement. |
Performance characteristics
Four parameter display, any combination of parameters, up to 12 measurement parameters 7-inch 16:9 TFT LCD display, resolution 800x480 RGB 0.05% basic measurement accuracy, fast test speed (200 times/sec) 20Hz-5MHz test frequency, resolution 10 mHz Up to 200 times/s measurement speed Automatic level control ALC function of test voltage or current 30 Ω, 100 Ω, 50 Ω, 10/CC four different signal source output impedance Built-in comparator, 10 file sorting and file counting function Frequency response curve drawing analysis function 10-point list scan function Internal -5V~+5V DC bias voltage source Optional ±10V (±100mA) and 1 A internal DC bias source 100 sets of internal setting files are saved or recalled, and 500 sets of test files are saved or recalled by U disk The instrument software version can be upgraded and updated through USB HOST U disk can support format FAT16, FAT32 file system Standard RS232C, HANDLER, USB HOST, headphone interface, optional GPIB, LAN interface |
Technical index
Operating temperature, humidity | 0℃-40℃,90%RH | |
Power requirements | Voltage | 99V-121V 198V-242V |
frequency | 47.5Hz-63Hz | |
Power consumption | ≤80VA | |
Volume (W*H*D) | 398mm×129mm×370mm | |
weight | About 9kg |
Technical Parameters
Instrument model | ZC2878 | ZC2877 | ZC2876 | ||||
Measurement function | Test parameters | |Z|,|Y|,C, L,X,B,R,G,D,Q,θ,DCR | |||||
Basic measurement accuracy | 0.05% | 0.1% | |||||
Equivalent Circuit | Series Parallel | ||||||
Math function | Absolute deviation | ||||||
Range method | Automatic, hold, manual selection | ||||||
Trigger method | Internal, manual, external, bus | ||||||
Measuring speed (≥1kHz) | Fast: 75 times/sec (fastest) | Fast: 200 times/sec (fastest) | |||||
Average times | 1—255 | ||||||
Delay time | 0-60s, step by 1ms | ||||||
Calibration function | Open circuit / short circuit / load | ||||||
Test terminal configuration | Five ends | ||||||
List scan | 10-point list scan function | ||||||
Display method | Direct reading, Δ, Δ%, V/I (measured voltage/current monitoring) | ||||||
monitor | 6-bit resolution, 800×480 RGB 7-inch 16: 9 TFT LCD display | ||||||
Test signal | Test signal frequency | 20 Hz-1MHz, 10mHz resolution | 20 Hz-2MHz, 10mHz resolution | 20 Hz-5MHz, 10mHz resolution | |||
Output impedance | 30Ω, 100Ω, 50Ω, 10/CC can be selected | ||||||
Test signal level | Normal: 5 mV-2V | Normal: 5 mV-5V Accuracy: 10%, 1 mV step | |||||
DC bias source | internal | 0V,1.5V,2V | 0V-5V continuously adjustable, 1mV step | ||||
Optional | ZC6802A: 0-10V DC bias voltage, 0-100mA DC bias current | ||||||
ZC6802B: 0-1A DC bias current | |||||||
Display range | |Z|, R, X | 0.01m Ω — 99.9999 MΩ | |||||
DCR | 1 mΩ — 99.9999 MΩ | ||||||
|Y|, G, B | 0.00001µS — 99.9999 S | ||||||
C | 0.00001 pF — 9.9999 F | ||||||
L | 0.00001 µH — 9999.99 H | ||||||
D | 0.00001 — 9.9999 | ||||||
Q | 0.00001 — 9999.9 | ||||||
θ (DEG) | -179.999°— 179.999° | ||||||
θ (RAD) | -3.14159 — 3.14159 | ||||||
other | Comparator function | Ten files: (Nine files are qualified, one file is unqualified), and there is an auxiliary file AUX | |||||
Memory | 100 sets of internal instrument settings for storage/recall | ||||||
interface | RS-232C, HANDLER, GPIB(optional), LAN (optional), USBTMC, USBCDC |